Wiring; Table 2 Dvs300 Input And Output Power Characteristics - Webasto DVS300 Installation Manual

Intelligent fast-charging system
Table of Contents

Advertisement

Intelligent Fast-Charging System

4.5. Wiring

4.5.1. General Guidelines
4.5.1.1. See Table 2, Table 3, Table 4, Table 5, and Table 6 for input/output parameters.
4.5.1.2. See Figure 11 for the DVS input/output wiring. See Figure 12 for the field wiring. See Figure 13 for
the suggested power station wire routing. Use only UL-approved conductors and lugs for the
system wiring.
NOTE
External wiring and lugs are not provided.
Parameter
Input Voltage
Input Frequency
Number of Input Phases (Excluding Ground)
Minimum Circuit Breaker Inrush Rating
Minimum Disconnection Switch Voltage Rating
Charge Port Output Voltage
Charge Port Output Current
Maximum Circuit Breaker Rating
Input Current at Rated Output
Minimum Input Conductor Size
Minimum Grounding Conductor Size
Maximum Output Power
31504-76-0101
GSE Installation Guide for the DVS300/330/400 and MVS330/400

Table 2 DVS300 Input and Output Power Characteristics

Reference National Electrical Code. ANSI/NFPA 70.1999
Page 23 of 40
Value
480 VAC
60 Hz
Three
500A
600 VAC
0−120 VDC
0−500A
50A
50A
6 AWG
8 AWG
30 kW
Webasto Charging Systems, Inc.
Value
600 VAC
60 Hz
Three
500A
600 VAC
0−120 VDC
0−500A
40A
32A
8 AWG
8 AWG
30 kW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvs330Dvs400Mvs330Mvs400

Table of Contents