3.3

Safety distances

b
Fig. 1: Safety distances (view from above) up
c
When setting up in the room the following safety distances
from combustible materials (minimum distances - see also
nameplate) must be adhered to.
b
Caution: The floor in the radiation area of the glass firebox
door must be non-combustible.
Note that the room in which the stove is installed must have
at least one door / one window leading to the outside, or
a
be directly connected to such a room. Other heating appli-
ances and extractor bonnets must not be operated together
with this heating appliance as part of the room air system.
This pellet stove is positioned on the floor and aligned hori-
zontally, observing the safety distances. The height of the
adjustable feet can be altered.
EN
• a) 750 mm (at the front in the radiation area of the door)
• b) 50 mm (at the sides)
• c) 50 mm (rear)