12.3.3 Display - status display

1
Fig. 43: Status display
1 Status line
3 Room temperat-
ure display

12.4 Functions

12.4.1 Function - air distribution module, controlling the strength of the fan

An air distribution module is available as an option for RUBY. It can be used to heat an extra room via
warm air. The warm air is sucked from the back wall of the firebox.
For installation and other information, please contact your Austroflamm dealer.
External combustion air supply
Every combustion requires oxygen. This is drawn from the environment of the heating appliance.
In modern buildings the outside covering is very thick. Therefore there is an insufficient flow of fresh
combustion air. In such cases the supply of external combustion air is necessary. This is required even
with the use of aeration and ventilation systems in the home.
NOTICE
The combustion air connection is marked on the rear of the appliance with a supply air symbol
2
3
2 Start / stop func-
tion
EN
The stove is started or stopped by pressing the start / stop
button for longer than 2 seconds.
12 | Operation
.