SiUS092230EA
Wireless Remote
1. Slide down the cover and take it off.
Controller
2. Cut the address setting jumper J4.
Caution
Replace the remote controller if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
4.3
Jumper and Switch Settings
Reference
For the location of the jumper, refer to 25 page.
Part 7 Trial Operation and Field Settings
Be careful not to cut the jumper J8.
Jumper
on indoor
Function
unit PCB
Fan speed setting when
compressor stops for
JB
thermostat OFF.
(effective only at cooling
operation)
Power failure recovery
function
JC
Field Settings for FTXR Series
(R25252)
When connected
(factory setting)
The fan stops.
Auto-restart
When cut
Fan speed setting;
Remote controller setting
The unit does not
resume operation after
recovering from a power
failure. Timer settings
are cleared.
213