SiUS092230EA
2. Motions (in cooling)
In FAN operation, the fan speed is reduced by 60 rpm when no one is in the area.
When there is no signal from the motion sensor in 20 minutes, the microcomputer judges that
3. Airflow direction in 2-area INTELLIGENT EYE operation
Detection method: The opposite area of detected area is set as the target direction.
1. Detection signal ON in both areas A and B: Shift the airflow direction to area B (left side)
2. Detection signal ON in area A: Shift the airflow direction to area B (left side)
3. Detection signal ON in area B: Shift the airflow direction to area A (right side)
4. Detection signal OFF in both areas A and B: No change
When the detection signal is OFF for 20 minutes in both areas A and B, the unit starts energy
saving operation.
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
Part 4 Functions and Control
within
20 min.
ON
Detection signal
OFF
Target temperature
ON
Remote controller
OFF
Sensor button
ON
Operation
OFF
Fan speed (#)
OFF
nobody is in the room and operates the unit at a temperature shifted from the target
temperature. (Cooling/Dry: 1 ~ 2°C (1.8 ~ 3.6°F) higher, Heating: 2°C (3.6°F) lower, Auto:
according to the operation mode at that time)
Left
20 min.
n
Reset
1 ~ 2°C (1.8 ~ 3.6 °F)
Set speed
60 rpm
Indoor unit
Human
Area A
Area B
Functions for FTXR Series
within
20 min.
n
Reset
Set speed
Wall
Top view
Right
(R3853)
within
20 min.
n
Reset
R4003436
49