Field Settings

5.2.3 Jumper and Switch Settings

<Floor Standing Type: FVXS Series>
Switch (on indoor unit
<Floor / Ceiling Suspended Dual Type>
Switch (on indoor unit
For the location of the jumper and the switch, refer to the following pages.
257
Jumper (on indoor
unit PCB)
JB
Fan speed setting
when compressor
stops for thermostat
OFF. (effective only
at cooling operation)
JC
Power failure
recovery function
PCB)
SW2-4
Upward airflow limit
setting
PCB)
SW2
Installation style
changeover
FTXG25/35/50JV1BW(A): page 47
CTXS15/35/K2V1B, FTXS20/25K2V1B: page 49
FTXS35/42/50K2V1B, FTXS25/35/42/50J2V1B, ATXS20/25/35/42/50G2V1B: page 51
FTXS60/71GV1B: page 53
FVXG25/35/50K2V1B: page 55
FVXS25/35/50FV1B: page 57
FLXS25/35/50/60BAVMB: page 59
FDXS25/35E7VMB, FDXS50/60C7VMB: page 61
Function
When connected
(factory set)
Fan speed setting ;
Remote controller
setting
Auto-restart
Function
OFF (factory set)
Exposed or half
embedded
installation
Function
FLOOR
(factory set)
When installed as
the floor mounted
type
SiBE121135_A
When cut
Fan speed setting; "0" (The fan
stops.)
The unit does not resume
operation after recovering from a
power failure. Timer settings are
cleared.
ON
Set the switch to ON position
when you install the indoor unit
embedded in the wall to avoid
condensation.
CEILING
When installed as the ceiling
suspended type
Trial Operation and Field Settings