5.7.

Configuration types

Metered:
The controller monitors the volume of water used. Once it calculates that there is not enough capacity
for the next days operation, a regeneration cycle will be initiated immediately or at a preset time.
Time clock:
The controller will regenerate based on a set time of operation days.
Remote regen start
The controller will get a signal from a separate device to start the regeneration.

5.7.1. Single valve (System #4)

As named, this system work with only one valve. The regen can be initiated upon the treated volume
(delayed or immediate), time clock or an external remote regen signal.
Inlet
Valve
Outlet
Meter
Tank

5.7.2. Multiple valves with lockout (System #5)

This system works with 2 to 4 valves.
All tanks in parallel are supplying treated water. Each unit in the system has its own flow meter. The
controller will delay the start of a regeneration if another unit is already regenerating. Once that unit
has completed a regeneration cycle and returned to service, the unit with longest regeneration queue
time will begin regeneration. Only one unit regenerates at the time.The regen can be trigged on a
volumetric or remote signal.