Installer Manual Fleck 2910 - NXT - Programming
6.4.4. System size
Set the number of valves to be connected (2 to 4 valves) in the system.
A
Note
Only visible in multiple valve systems and only present on the master #1 valve.
Options:
•
2 valves in the system;
•
3 valves in the system;
•
4 valves in the system.
H
Adjust the system size with
→ Default setting: 2 valves.
I
Press
to validate the selection and advance to the next
parameter.
6.4.5. Regeneration type
Select the regeneration type.
Options:
•
Timeclock delayed: Regeneration will take place, at the programmed regeneration start up time,
after predetermined delay set up in day elapsed.
•
Volume delayed: Regeneration is requested when the volume of treated water reaches the
reserve capacity and will take place, at the programmed regeneration start up time.
•
Volume immediate: Regeneration is requested when the capacity is fully depleted. The
regeneration starts immediately.
J
Set regeneration type with
K
Press
to validate the selection and advance to the next
parameter.
6.4.6. Valve type
Select which valve is being used with the NXT.
Options:
•
2750;
•
2850;
•
2900/2910;
•
3150;
•
3900.
L
Set valve type with
→ Default setting: 2750
M Press
to validate the selection and advance to the next
parameter.
54 / 98
and
.
and
.
and
.
SYSTEM SIZE
2 VALVES
REGEN TYPE
TIME CL DELAYED
VALVE TYPE:
Ref. MKT-IM-002 / A - 18.11.2016
:
2750