6.
Programming
6.1.
Display
6.1.1. During service
1. System type
2. Valve address
3. Valve status
4. Flow indicator
5. Time of the day
6. Operating mode
6.2.
Commands
A
Note
At any time, press D to return to the home screen without saving.
A
Note
Menus are displayed in a defined and incremental order.
A
Press
to pass to the next step.
B
Use
to move the cursor to the next digit.
C
Use
and
D
Press D at any time to exit programming mode without saving.
Ref. MKT-IM-002 / A - 18.11.2016
1
2
7#1 SRV* 08:26HR
6
→ #4: single valve;
→ #5: lockout system, 2 to 4 valves;
→ #6: parallel system, sequential regenerations, 2 to 4 valves;
→ #7: duplex alternating system, 2 valves;
→ #9: alternating system, 2 to 4 valves;
→ #14: demand system, 2 to 4 valves.
→ #-: single valve;
→ #1: address 1, lead valve;
→ #2: address 2;
→ #3: address 3;
→ #4: address 4.
→ CHG (change of state): lower drive changes position on double piston
valve;
→ INI (initializing): after a power failure or a change in the programming,
the controllers initializes for approximately 30 seconds;
→ RGQ (regeneration queued): in a meter delayed system, the reserve
capacity has been entered or a manual regeneration has been registered;
→ LCK (lock): the controllers has acquired the lockout signal;
→ SRV (service): valve in service;
→ SBY (standby): valve in standby.
→ Rotates when flow is going through the meter.
→ Remaining volume in volumetric mode;
→ Remaining days before a regeneration in timeclock mode.
to adjust the values.
Installer Manual Fleck 2910 - NXT - Programming