System Type; Valve Address In The System - Pentair FLECK 2910 NXT Installer Manual

Hide thumbs Also See for FLECK 2910 NXT:
Table of Contents

Advertisement

6.4.2. System type

Select the system in which the valve(s) operate(s).
Options:
4: single valve;
5: multiple valve with lockout;
6: multiple valve with consecutive regenerations;
7: duplex alternating;
9: multiple valve, alternating;
14: demand recall.
D
Set the system type with
E
Press
to validate the selection and advance to the next
parameter.

6.4.3. Valve address in the system

Set the valve position in the system.
A
Note
Only visible in systems 5, 6, 7, 9 and 14.
A
Note
The number #1 is the lead valve (master) and contains the programmed parameters used
by the other controllers in the system in order to control the regeneration and service or
standby positions.
Options:
Address #1: valve 1, lead (master);
Address #2: valve 2;
Address #3: valve 3;
Address #4: valve 4.
F
Set the valve position with
→ Default setting: valve 2 address #2.
G
Press
to validate the selection and advance to the next
parameter.
Ref. MKT-IM-002 / A - 18.11.2016
Installer Manual Fleck 2910 - NXT - Programming
and
.
and
.
Example: 4 Single valve
SYSTEM TYPE
SIMPLEX
Example: 5 multiple valves
5#1 SRV* 10:15HR
VOLUME
25000L
Example: Valve #1 (master)
ADDRESS 
VALVE
Example: Valve #2
ADDRESS 
VALVE
:4
#1
#2
53 / 98

Advertisement

Table of Contents
loading

Table of Contents