5.7.

Regeneration types

Softener metered delayed:
The controller measures the water usage. The system regenerates at the pre-programmed time after
the calculated system capacity is depleted. The controller calculates the system capacity by dividing
the unit capacity by the feedwater hardness.
Softener time clock delayed:
The controller will regenerate based on a set number of days of operation. The controller will
regenerate the system, at the pre-programmed regeneration time, when the number of days since
the last regeneration equals the set number of days.
Filter Metered Immediate:
Regenerates the system immediately after the selected volume override value is depleted. A filter
immediate controller will also start a regeneration cycle at the selected regeneration time if a number
of days equal to the day override pass before water usage depletes the calculated system capacity.
5.8.

Electrical connections

Ref. MKT-IM-005 / C - 22.05.2018
Installer Manual Fleck 5800 - LXT - Installation
12 VDC
Main motor
Flow meter
12 VDC IN