Getting Started and Commonly Used Functions
reinserted into the device, or a project is downloaded to the device with the location set to "Hard
disk".
Please note that if any scripting has been done towards the database, then these scripts need to be
manually adapted to work with the new location (flash or SD card).
If Audit Trail is enabled for the project and if the database is stored on SD card, the transfer client
will not provide the option to keep/remove audit trail in an existing project. It will always keep the
audit trail database. If the user wants to clear the audit trail database for the same project, the SD
card needs to be inserted into a PC and manually delete the audit trail database file.
It is also recommended to track the flash wear status in your iX Developer project.
The following System Tags can be used for that purpose:
System Tag
Flash Memory Life Time
Used
Flash Memory EOL Info
Please see document
Best Practice Database on SD card or flash memory
information.
2023-06
The usage of the device lifetime (in percent).
Information about the flash memory end of life. The three
possible values are:
• Normal
• Warning - Consumed 80% of reserved block
• Urgent
36
Description
for more detailed
Beijer Electronics, MAEN363
Need help?
Do you have a question about the BoX2 base v2 and is the answer not in the manual?
Questions and answers