Infocenter Fault Codes - Toro 41393TE Software Manual

Turf sprayer with excelarate spray system
Hide thumbs Also See for 41393TE:
Table of Contents

Advertisement

Advisories Table (cont'd.)
Condition
Engine Stopped
Pump Start Prevented
Pump Start Prevented
Pump Start Prevented
Pump Start Prevented
Pump Turned Off
Driving prevented
Tank Status
Tank Status
Parameter Status
Parameter Status
Booms Turned Off
GeoLink Configuration
GeoLink Configuration
Flow Rate Meter
Neutral switch

InfoCenter Fault Codes

Fault codes display on the InfoCenter screen when there is a problem with the electronic or computer systems.
For example, if the fuse for the Toro electronic controller is open, the InfoCenter displays fault code 1. Refer
to the fault code table for a list fault codes and recommended actions.
Fault Code Table
Fault ID
1
2
Code
103
202
203
204
205
206
302
402
403
502
503
802
902
903
1002
1102
Affected Component or
System
Master Toro electronic
controller (TEC)
Output fuse
Qualifier
Parking brake set
Boom active
Out of seat and parking brake
not set
Pump start when vehicle
stopped
Engine starting
Out of seat
Parking brake engaged while
driving
Low spray tank volume
Rinse pump active
Wrong parameter value entered
A value is outside the range of
accepted values
Speed dropped
GeoLink controller conflict
InfoCenter setting
No flow signal
Neutral switch signal
Description
A signal to or from the Master
TEC are out of range.
A fuse for the master TEC is
open.
29
Display Text
Engine stop due to parking
brake engaged
To start pump, turn booms off
To start pump, must be seated
or set parking brake
To start pump, move vehicle
To start pump, stop cranking
engine
To start pump, remain seated
To continue driving, release
parking brake
Tank status, volume low
Tank status, rinse pump on
Parameter status, invalid value
Parameter status, invalid data
defaults used
Booms turned off, stopped or
moving too slowly
GeoLink Configuration, check
GeoLink controllers
GeoLink configuration, check
InfoCenter settings
Flow meter, no flow detected
Neutral switch, motion while in
neutral
Recommended Action
Call your authorized Toro
distributor.
Replace the fuse; refer to the
operator's manual.