Evaluating the Which Type of Flow Calibration
to Perform
Use the Sprayer Sections Table to help determine
how you typically spray turf with the machine and
which flow calibration to perform.
Note:
You can perform a combination of up to 3 flow
calibration types.
Sprayer Section Table
Perform the 3-boom calibration
3 sprayer sections
I also spray with 2
Perform the 2-Boom
sprayer sections:
Calibration
Left and Center
sections (OR)
Right and Center
sections (OR)
Right and Left
sections
I also spray with 1
Perform the 1-Boom
sprayer section:
Calibration
Left sprayer section
only (OR)
Center sprayer
section only (Or)
Right sprayer
section only
3 boom calibration: Always perform the calibration
for the 3 sprayer sections when you change the
nozzles to increase or decrease the range of
application rates.
Note:
If you do not perform the optional 2 boom
calibration or 1 boom calibration, the sprayer uses
the calculations from the 3-boom calibration in all
sprayer-section combinations.
Optional 2 boom calibration: Calibrate the left and
center sprayer sections or the right and center sprayer
sections or the left and right sections if you typically
spray with those section combinations. Perform this
optional calibration after performing the 3 sprayer
section calibration.
Note:
The calibration you perform for two sprayer
sections is used whenever you spray with any
combination of 2 sprayer sections.
Note:
You can calibrate only for 1 pair of sprayer
sections for the 2-boom calibration. Calibrate from the
pair of sprayer sections that you use the most. The
sprayer system uses the 2-boom calculation when
you spray with either the left and center or right and
center section combinations.
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Optional 1 boom calibration: Calibrate the left
or center or right sprayer section if you typically
spray with 1 sprayer section. Perform this optional
calibration after performing the 3-sprayer-section
calibration and 2-sprayer-section calibration.
Note:
You can calibrate only 1 of the 3 sprayer
sections for the 1 boom calibration. Calibrate from the
sprayer section that you use the most. The sprayer
system uses the 1-boom calibration when you spray
with the left, center, or right section.
Preparing for the Flow Test
1.
Ensure that the nozzles that you intend to use
are in the active spray (down) position
40).
Important:
All nozzles in the active position
must be the same color.
Note:
For best results, nozzles in the active
position should have approximately the same
amount of wear.
1. Reserve nozzle position
2.
Press buttons 1 or 2 on the
sub-menu to navigate to the
41).
15
Figure 40
2. Active spray position
CALIBRATION
option
FLOW
(Figure
g192604
(Figure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi pro 5800-gMulti pro 5800-d

Table of Contents