Resistance Measurement; Diode Test; Frequency Measurements - AEMC 603 User Manual

Clamp-on meter
Table of Contents

Advertisement

4.2.7

Resistance Measurement

Measurement Range (1)
Specified Measurement
Range
Accuracy
Resolution
Open-circuit Voltage
Measurement Current
Note (1) Above the maximum display value, the display unit indicates "OL".
The "-" and "+" signs are not managed.
Specific Specifications in MAX/MIN mode:
Accuracy: add 1% R to the values of the table above.
Capture of the extreme: approximately 100ms.
4.2.8

Diode test

Measurement Range
Specified Measurement Range
Accuracy
Resolution
Measurement Current
Indication: junction reversed or
open-circuit
Note: The "-" sign is disabled for the diode test function.
4.2.9

Frequency Measurements

4.2.9.1
Voltage
Measurement Range (1)
Specified Measurement
Range
Accuracy
Resolution
0.0 to
999.9Ω
1 to 100% of the
measurement range
0.1Ω
550µA
1 to 100% of the measurement range
"OL" is displayed when the measured
5.0 to 999.9Hz
1 to 100% of the
measurement
range
0.1Hz
34
1000 to
9999Ω
0 to 100% of the
measurement range
± (1% R +5cts)
1Ω
≤ 3.6V
100µA
0.000 to 3.199V
± (1% R + 3cts)
0.001V
0.55mA
voltage >3.199V
1000 to 9999Hz
0 to 100% of the
measurement range
± (0.4% R + 1ct)
1Hz
10.00 to
99.99kΩ
10Ω
10µA
DC
10 to 19.99kHz
10Hz

Advertisement