Environmental Variations - AEMC 603 User Manual

Clamp-on meter
Table of Contents

Advertisement

4.7

ENVIRONMENTAL VARIATIONS

Condition of
Influence
-4° to +131°F
Temperature
(-20° to +55°C)
Humidity
10 to 90% RH
10Hz to 1kHz
1kHz to 3kHz
Frequency
10Hz to 400Hz
400Hz to 2kHz
Position of
Any position
the conductor
on the internal
in the
perimeter of
jaws
(f≤400Hz)
Adjacent
conductor
touching the
carrying a
current of
perimeter of
150A
or
DC
RMS
Conductor
enclosed by
0 to 500ARMS
the clamp
Application of
0 to 1000V
a voltage on
the clamp
Peak factor
to 1500A peak
1400V peak
*Note in Temperature: Influence specified until 1000 A DC
Range of
Measurement
Influence
Influenced
the jaws
Conductor
external
the jaws
DC
or RMS
1.4 to 3.5,
limited
V
AC
V
DC
0.1% R/10°C
A*
1% R/10°C
T°C
(0.2% R +1°C)/10°C
0.1% R/10°C + 2ct
Hz
V
A
V
A
A
A
V
A
A (AC)
V (AC)
38
Influence
Typical
-
0.5% R/10°C + 2ct
1.5% R/10°C + 2ct
(0.3% R +2°C)/10°C
0.1% R/10°C + 3ct
0.1% R
1% R
8% R
1% R
4% R
2% R
40 dB
< 1ct
< 1ct
1% R
1% R
MAX
0.1% R/10°C
0.1% R + 1ct
1% R + 1ct
9% R + 1ct
1% R + 1ct
5% R + 1ct
4% R + 1ct
45 dB
1ct
3% R + 1ct
3% R + 1ct

Advertisement

Table of Contents
loading

Table of Contents