2.3 CONTROL FUNCTIONS

EcoMode (Economy Control Switch)
  Turn EcoMode ON to minimize fuel consumption. In this mode the
engine will dynamically meet the demand of the electrical load and will
automatically go into an idle state if all loads are disconnected.
  Before connecting or removing a high load device to the generator, turn
EcoMode OFF until that device has reached running power.
  When EcoMode is OFF, the engine runs at full speed.
Reset Button
  If the red overload indicator light is on, press and hold the reset button
for 1 second until the overload indicator light turns off and the green
output indicator light turns on. This will recover generator output without
shutting down the engine.
  If the generator is running normally, the RESET button will have no effect.
NOTE
  The RESET button is available a maximum of 5 times for every full start
of the generator. Shut down the generator and restart using the power
switch to refresh available resets.
Output and Overload Indicator
  In normal operation, the green output indicator light (READY) will remain
on.
  If the generator is overloaded (producing more than 1600W) or a
connected appliance has short-circuited, the output indicator light will
turn off and the overload indicator light will turn on.
USB Ports
  A total of 3.1A is available at 5.0V. A single port can draw the full 3.1A or
it will be distributed as needed. For example, a 1A device will only draw
1A.