Stopping The Generator; Control Panel; Welding Process - Hyundai FULLPOWER 65213 Manual

Power generator
Table of Contents

Advertisement

Available languages

Available languages

OPERATION OF DIESEL GENERATING SET

Stopping the generator

a) Before stopping the generator stop any machine connected.
b) Move the thermal of 30mA leakage breaker to the lower position so the generator is not giving power.
c) Let the generator run for at least 3 min. without load in orther to cool it down.
d) Stop the generator
-
Manual start: Release the speed controller from RUN to
STOP position by pressing on the side of it.
- Electric start: Turn the key to the off position
- Remote control: Push the lock open key on the remote
controller.
e) For Soundproof generator there is an emergency stop button on
the control panel used to stop the generator in case of emergency.
Use it only in case of emergency as if stop the generator with load
can damage the AVR.
Battery
a) The standard battery is maintenance free type, no need to add any liquid.
b) During the operation, the generator can automatically charge the battery.
c) If the generator is used for stand-by application, should remove the battery.
d) If the voltage battery is too low, the generator will be difficult to start. Please charge the battery
by charger before starting the generator.
NOTE 1: Do not start more than two machines in the same time,
Only start them one by one.

Control panel

There are two kind of control panels, LED3 and LED4 type: LED3: This control panel has protec-
tion for the overload under thermal breaker.
The LED display is giving information of the voltage, running hours, frequency.
LED4: The main feature of this display is the protection of the overload over the measurement of the current.
Once the display is receiving power will show the different information of the generator performance.
By pressing the MODE key will display the information according Voltage, current, Power and frequency
Protection settings: The LED4 display can settle different values for the protection of the genera-
tor, default setting from factory can be modified but is not recommentd to do.

Welding process

Connect the welding cables to the generator
Be sure the cables are not cross
Select the desired intensity in the control panel.
Weld the desired parts.
Note: DO NOT USE ELECTRODE WITH DIAMETER OVER 4mm.