2.3 CONTROL FUNCTIONS

AC Circuit Breakers
  While the generator is running, the breakers should be put in the ON
position.
  If the current has exceeded its limits it will automatically pop out to the
OFF position. Reduce the electrical load on the generator and push the
button back to the ON position.
DC Circuit Breakers
  The DC circuit breaker automatically shuts off when the charging circuit
is overloaded.
  If the current has exceeded its limits the breaker will automatically pop
out to the OFF position. Reduce the electrical load on the generator and
push the button back to the ON position.
EcoMode (Economy Control Switch)
  Turning EcoMode to ON is recommended for minimizing fuel
consumption. In this mode the engine will dynamically meet the demand
of the current electrical load and will automatically go into an idle state if
all electrical loads are disconnected.
  Before connecting or removing a high load device to the generator, turn
EcoMode to OFF until that device has reached running power.
  When EcoMode is OFF, the engine runs at full speed.
Ground Terminal
WARNING!
Before using the ground terminal consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local
laws and codes that apply to the intended use of the generator.
  Floating Neutral. The ground terminal is connected to the non-current
carrying metal parts (such as the fuel tank), the frame, and the ground
terminals of the AC outlets.
Low Oil Indicator Light
  The oil alert system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase. Before the oil level in the
crankcase reaches an unsafe limit, the oil alert system will automatically
shut down the engine (the power switch remains in the ON position).
  If the oil alert system shuts down the engine, the low oil indicator light
7