ATTO Technology FibreBridge 2300E Installation And Operation Manual page 30

Hide thumbs Also See for FibreBridge 2300E:
Table of Contents

Advertisement

8.1.5 SCSI configuration commands
The SCSI ports are configured with default settings but may be customized to your specifications using
the CLI commands in this section.
CLI commands are case insensitive (upper and
lower case allowed anywhere).
ScsiInitID
Specifies the SCSI initiator ID to be used on the specified SCSI port. All maps coinciding with the user-specified ScsiInitID must be set to offline
and will become invalid upon issuing this command
Limits: [0-15] wide [0-7] narrow
Action: set ScsiInitID [sb [0-15] ]
SaveConfiguration
ScsiPortBusSpeed
Controls the transfer rate at which the FibreBridge will attempt to negotiate with its SCSI devices.
Limits: Fast SCSI, Ultra SCSI, Ultra 2 SCSI (valid only if
FibreBridge has LVD-capable SCSI ports)
Actions: set ScsiPortBusSpeed [Port Number [ fast|
ultra| ultra2]
SaveConfiguration
ScsiPortList
Returns a list of available SCSI ports and their current status
Limits: valid status values are OK and Failed
Action: none
ScsiPortResetOnStartup
Specifies whether the SCSI port should be reset on power-up or not
Limits: [enabled | disabled]
Action: set ScsiPortResetOnStartup [sb [enabled |
disabled] ]
SaveConfiguration
ScsiPortSelTimeout
Indicates the time, in milliseconds, that the bridge waits for a response from a SCSI device on the selected port after a selection request. Setting a
long selection time-out value can result in the host generating system time-out.
Limits: [256| 128|64|32|16|8|4|2|1]
Action: set ScsiPortSelTimeout [sb [256 | 128 | 64 | 32 | 16
| 8 | 4 | 2 | 1]]
SaveConfiguration
ScsiPortSyncTransfer
Specifies whether synchronous SCSI transfers should be negotiated with devices on the specified SCSI port.
Limits: [enabled | disabled]
Action: set ScsiPortSyncTransfer [[sb [enabled |
disabled] ]
SaveConfiguration
25
ATTO Technology FibreBridge 2300E/R/D Installation and Operation Manual
Commands generally follow a standard format:
[Get | Set] Command [Parameter 1 | Parameter 2] followed by
the return or enter key
Information: get ScsiInitID
Default:
Information: get ScsiPortBusSpeed
Information: ScsiPortList
Default: enabled
Information: get ScsiPortResetOnStartup [sb]
Default: 64ms
Information: get ScsiPortSelTimeout [sb]
Default: enabled
Information: get ScsiPortSyncTransfer [sb]