ATTO Technology FibreBridge 2300E Installation And Operation Manual page 28

Hide thumbs Also See for FibreBridge 2300E:
Table of Contents

Advertisement

8.1.4 Fibre Channel configuration commands
The Fibre Channel ports are configured with default settings but may be customized using CLI.
DispFcPortDB
Used to display the contents of the specified FC port's internal port database which contains Fibre Channel addressing information for each FC
target device visible to the FibreBridge.
Action: none
FcAck0
Specifies whether ACK0 or ACK1 will be returned in response to a Class 2 FC data frame or sequence.
Limits: Enable sends ACK0 at the end of a sequence. Disable returns an ACK1 frame for each data frame.
Action: set FcAck0 [enabled | disabled]
SaveConfiguration
FcClass2
Specifies if the FibreBridge will support Fibre Channel Class 2 (multiplexed) service. The FibreBridge uses Class 3 service by default.
Limits: [enabled | disabled]
Action: set FcClass2 [enabled | disabled]
SaveConfiguration
FcConnMode
Controls/reports the connection mode the FibreBridge uses when communication across a Fibre Channel network, either to an arbitrated loop (FC-
AL) when you select loop mode, or point-to-point when you choose ptp.
Limits: applies to all Fibre Channel ports
Actions: set FcConnMode [loop | ptp]
SaveConfiguration
FcFairArb
Turns the Fibre Channel Arbitrated Loop (FC-AL) arbitration fairness on or off. When enabled, the FibreBridge follows the arbitration fairness
rules on the FC-AL.
Limits: applies to all Fibre Channel ports
Actions: setFcFairArb [enabled | disabled]
SaveConfiguration
FcFullDuplex
When enabled, allows full duplex Fibre Channel communication between the FibreBridge and other Fibre Channel devices. Disable FcFullDuplex
results in half duplex mode.
Limits: applies to all Fibre Channel ports
Actions: setFcFullDuplex [enabled | disabled]
SaveConfiguration
FcHard
Used to enable or disable Fibre Channel hard address assignment. Under soft addressing, the FibreBridge loop address is assigned during loop
initialization. Use FcHardAddress (described below) if you enable hard addressing.
Limits: applies to all Fibre Channel ports
Actions: setFcHard [enabled | disabled]
SaveConfiguration
FcHardAddress
Sets/displays the value used as the FC-AL hard address. This hexadecimal value represents the address the FibreBridge will try to use if hard
addressing is enabled. When an optional address is not present, the current value is displayed.
Actions: set FcHard Address [fp |[address]]
SaveConfiguration
23
ATTO Technology FibreBridge 2300E/R/D Installation and Operation Manual
Information: DispFcPortDB <fp>
Returns: Node name, 24-bit port ID, 8-bit internal loop ID of each FC device
Information: get FcAck0
Returns: [fp] [fl] [sb] [st] [sl] [Online|Offline]
Default: Class 3 (DISABLED?)
Information: get FcClass2
Default: loop
Information: get FcConnMode
Default: on, enabling arbitration fairness
Information: getFcFairArb
Default: enabled
Information: get FcFullDuplex
Default: enabled, or hard addressing
Information: get FcHard
Default: 0 < = hard id < = 0x7d
Information: get FcHardAddress [fp]
verbose return: Port n FcHardAddress = 0x01