Actions: set ErrorLog clear
Returns: Error Logs cleared
IdentifyFibreBridge
Enabling this option causes the Ready LED on the front panel of the FibreBridge to blink until the parameter is disabled.
Actions: set IdentifyFibreBridge [enabled|disabled]
SaveConfiguration
LogEvent
Sets the switches which control the filtering performed when logging events.
Limits: To display from several different subsystems or
events, use a mask value equal to the logical OR of the
corresponding values. To display events from all
subsystems, enter [0x7F] as the mask
[subsystem] controls which subsystem's events display
0x01 FCP Processor/i960 Interaction
0x02 SCSCI Processor/i960 Interaction
0x04 Ethernet
0x08 Extended copy
0x20 NVARM & Flash
0x40 ECC failures
[status] [all]: all events regardless of status values
[ngood]: only events with a status value other than good
Actions: set LogEvent [enabled | disabled] |
[[subsystem] [event_level] [status]]
SaveConfiguration
ParityLog
Contains the parity error statistics for the FibreBridge since the statistics were last cleared. The set form sets the statistics to zero.
Limits: 65,535 maximum number of errors
Action: set ParityLog clear
SaveConfiguration
Performance
Returns the performance data for the Fibre Channel port you specify. Data includes the average rate (MBs per sec.) and number of I/Os measured
over the previous sampling period where a sampling period is approximately one second. Requesting performance data for a FC port which has
been disabled or has failed will result in the display of an error message ("ERROR Disabled Fibre Channel port" or "ERROR Failed Fibre Channel
port"). Reported performance may be affected by FC port and SCSI bus availability and saturation, SCSI device speeds and overall system use.
Limits: Successful SCSI Read (08h, 28h) and Write (0Ah, 2Ah) commands are considered I/Os.
Valid FC port (fp) entry is [0] for the FibreBridge 2300
Actions: none
POSTOutput
Returns the stored output of the most recent Power On Self Test.
Action: none
Information: get ErrorLog
Returns: The last error code save was xx
[An error of type xxx was detected since last error log clearing
Specific error text.]
Information: get IdentifyFibreBridge
Default: [disabled]
[event_level] controls what report level events display
0x01 Info: general information
0x02 Warning: unexpected situation/condition
0x04 Critical: operation limited/curtailed
0x08 Failure: hard failure
0x10 Other;
0x20 Debug: track events
Information: getLogEvent
Information: get ParityLog
Returns:
Parity Errors:
FibreChannel 0xnnn
SCSI 0xnnn
Information: get Performance <fp>
Verbose return:
[line count]
; fp
.MB/s.........
IO/s
[fp] [mmm.mmm] [nnn]
Information: get POSTOutput
22