ATTO FibreBridge diagnostic commands help validate FibreBridge operation and diagnose/isolate
FibreBridge faults.
Event logging is a mechanism for on-site
observation of internal FibreBridge behavior such
as tracing SCSI commands received over the
ClearEvent
Clears the contents of the event log.
Actions: ClearEvent
DispEvent
Sets the switches which control the filtering performed when displaying events.
Limits: To display from several different subsystems or
events, use a mask value equal to the logical OR of the
corresponding values. To display events from all
subsystems, enter [0x3F] as the mask
[subsystem] controls which subsystem's events display
0x01 FCP Processor/i960 Interaction
0x02 SCSI Processor/i960 Interaction
0x04 Ethernet
0x08 Extended copy
0x20 NVARM & Flash
0x40 ECC failures
[status] [all]: all events regardless of status values
[ngood]: only events with a status value other than good
Actions: set DispEvent [subsystem] [event_level]
[status]
SaveConfiguration
DisplayEvent
Results in a display of the current contents of the event log to the display. The log is filtered by the current switch settings as described in the
DispEvent command. If the optional all parameter is provided, the display filtering is temporarily suspended and all logged events are displayed
regardless of the current event filter switch settings.
Actions: DisplayEvent <all>
EccLog
ECCLog contains the Error Correcting Code statistics since the previous statistics were last cleared. The maximum number of errors is 65535. Get
form shows the statistics. The set form sets the statistics to zero.
Actions: set EccLog clear
Returns: Ecc Logs cleared
ErrorLog
Set form clears ErrorLog since previous error reported. Get form shows error messages since the report was last cleared.
Limits: Error type may be returned as [960 | Static Memory | Synchronous DRAM | ISP2200 | FibreChannel | Software] and one line
of descriptive text]
21
ATTO Technology FibreBridge 2300E/R/D Installation and Operation Manual
8.1.3 Diagnostic commands
Fibre Channel from the host and return of data and
status to the host.
Information: none
Default: [0x7F] 0x3F] [all]
[event_level] controls what report level events display
0x01 Info: general information
0x02 Warning: unexpected situation/condition
0x04 Critical: operation limited/curtailed
0x08 Failure: hard failure
0x10:Other
0x20 Debug: ATTO tracking events
Information: getDispEvent
Verbose return: DispEvent=SubSys:0xXX Lv1:0xXX
Status: [all | no good]
Information: none
Information: get EccLog
Returns: ECC Errors:
Single-bit 0xnnnn
Multi-bit 0xnnnn
POST Single-bit 0xnnnn
POST Multi-bit 0xnnnn
Last Error Address 0xyyyyyyyy