HearthStone AURORA 8906 Series Owner's Manual Installation And Operating Instructions page 29

Freestanding vent free gas fireplace
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
ECLIPSE VF 8906
Synchronizing the Remote and Valve Receiver Module
A code is selected automatically for all Mertik Maxitrol electronics from among 65,000 random codes available.
The receiver must learn the code of the handset, which is performed at the factory. If for any reason your
appliance stops responding to remote commands, it may be necessary to re-sync the two components. To
access the Valve Receiver Module, follow the instruction on page 16. Once you have access to the Receiver,
press and hold the receiver's reset button (see figure below) until you hear two (2) beeps. The first beep is short
and the second beep is long. After the second beep, release the reset button. Within 20 seconds press the
Small Flame button on the handset until you hear two additional short beeps confirming the code is set. If you
hear one long beep, this indicates the code has failed or the wiring is incorrect.
f i r e - p a r t s . c o m
Step 1: Locate Reset Button on Receiver
Step 2: Press and hold Reset button until
Step 3: Within 20 seconds, press Small
second beep is finished
Flame button on the remote
29