Installing or Replacing the Batteries
1. The valve control module is powered by four "AA" batteries. The batteries are mounted within the Valve
Receiver Module located behind the front stone panel, to the left of the valve. Refer to the illustration below.
2. Pull the Valve Receiver Module toward you, disengaging it from the retention clip.
3. Slide off the Battery compartment cover.
5. Install the 4 "AA" batteries, supplied, using the guides inside the battery pack to show you the correct battery
orientation.
6. Replace the battery compartment cover. Slide the Valve Receiver Module back into its home position.
7. The remote handset is powered by three "AAA" batteries. The battery access panel is located on the back of
the handset and simply snaps open to provide access to the battery compartment. Install the three batteries
as shown on the label inside the remote control battery compartment, then replace battery access panel.
f i r e - p a r t s . c o m
Placing the Burner Glass Media
The burner glass media poly-bag that you set aside when you unpacked the fireplace contains the
correct amount of glass material to cover the burner. DO NOT add any additional media to the media
supplied with your fireplace. The entire contents of the bag should be evenly distributed over the
burner tray. Locate the burner in the fireplace. Refer to the adjacent illustration.
Carefully clip one corner of the poly-bag to form a pouring spout. The opening should be large
25.
enough to allow the glass media to flow but not so large that you can't control the flow.
You will notice that the burner surface is designed with turned-up edges that form a tray to
26.
hold the glass media.