MPP Solar PIP3624MAX User Manual page 29

Solar inverter / charger
Table of Contents

Advertisement

31
Battery equalization voltage
33
Battery equalized time
34
Battery equalized timeout
35
Equalization interval
Equalization activated
36
immediately
Reset all stored data for PV
37
generated
power
output load energy
PIP3624MAX model default:
29.2V
Setting range is from 25.0V to 31.0V for PIP3624MAX model and
48.0V to 62.0V for PIP7248MAX model. Increment of each click is
0.1V.
60min (default)
120min (default)
30days (default)
Enable
If equalization function is enabled in program 30, this program can
be set up. If "Enable" is selected in this program, it's to activate
battery equalization immediately and LCD main page will show
"
". If "Disable" is selected, it will cancel equalization function
until next activated equalization time arrives based on program 35
setting. At this time, "
Not reset(Default)
and
27
PIP7248MAX model default: 58.4V
Setting range is from 5min to
900min. Increment of each click is
5min.
Setting range is from 5min to 900
min. Increment of each click is 5
min.
Setting range is from 0 to 90 days.
Increment of each click is 1 day
Disable (default)
" will not be shown in LCD main page.
Reset

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pip7248max