MPP Solar PIP3624MAX User Manual page 28

Solar inverter / charger
Table of Contents

Advertisement

AC output mode
(only for parallel model)
*This setting is only
28
available when the inverter
is in standby mode (Switch
off).
AC output mode
(only for parallel model)
*This setting is only
28
available when the inverter
is in standby mode (Switch
off).
Low DC cut-off voltage:
 If battery power is only
power source available,
inverter will shut down.
 If PV energy and battery
power are available,
inverter will charge
29
battery without AC
output.
 If PV energy, battery
power and utility are all
available, inverter will
transfer to line mode
and provide output
power to loads.
30
Battery equalization
Single: This inverter is used
in single phase application.
When the inverter is operated in 3-phase application, set up
inverter to be operated in specific phase.
L1 phase:
L3 phase:
PIP3624MAX model default:
22.0V
If self-defined is selected in program 5, this program can be set
up. Setting range is from 21.0V to 24.0V for PIP3624MAX model
and 42.0V to 48.0V for PIP7248MAX model. Increment of each
click is 0.1V. Low DC cut-off voltage will be fixed to setting value
no matter what percentage of load is connected.
Battery equalization
If "Flooded" or "User-Defined" is selected in program 05, this
program can be set up.
26
Parallel: This inverter is operated in
parallel system.
L2 phase:
PIP7248MAX model default: 44.0V
Battery equalization disable
(default)