Cad Drawing - ADJ XS 400 User Instructions

Table of Contents

Advertisement

REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
XS 400
female XLR connector on either end of the cable. Also remember that
DMX cable must be daisy chained and cannot be split.
Notice:
Be sure to follow figures two and three when making your own
DMX512
cables. Do not use the ground lug on the XLR connector. Do not con-
DMX+,DMX-,COMMON
nect the cable's shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR's outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 O T
3-PIN XLR
XLR Male Socket
1 Ground
2 Cold
2 Cold
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
3 Hot
Figure 3
Special Note: Line Termination.
POWER
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
avoids signal transmission problems
1
1
DMX512 IN
and interference. It is always advisable
3
3
3-PIN XLR
2
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
ADJ Products, LLC - www.adj.com - XS 400 User Manual Page 6
SOUND
POWER
COMMON
DMX +
1
1
DMX512 IN
3
3
3-PIN XLR
DMX -
2
2
XLR Female Socket
XLR Pin Configuration
1 Ground
Pin 1 = Ground
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
Pin 2 = Data Compliment (negative)
INPUT
3 Hot
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
DMX Set Up
XS 400
5-Pin XLR DMX Connectors.
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
POWER
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
Termination reduces signal errors and
Data Compliment (- signal)
avoids signal transmission problems
1
and interference. It is always advisable
3
to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
Figure 2
and PIN 3 (DMX +) of the last fixture.
XS 400
POWER
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
Some manufactures use 5-pin DMX-
POWER
3-Pin XLR to 5-Pin XLR Conversion
Conductor
3-Pin XLR Female (Out)
Ground/Shield
Pin 1
Pin 2
Data True (+ signal)
Pin 3
Not Used
Not Used
169.9
145
ADJ Products, LLC - www.adj.com - XS 400 User Manual Page 7
比例 25.400
DMX Set Up
5-Pin XLR Male (In)
Pin 1
Pin 2
Pin 3
Pin 4 - Do Not Use
Pin 5 - Do Not Use

CAD Drawing

123.6
100

Advertisement