Flavel FRLCP0MN Installation And Maintenance Instructions Manual page 10

Table of Contents

Advertisement

Closure plate.
a)
Fit the closure plate to the fireplace opening and ensure that it has a flat
sealing area of at least 10mm sealed on all sides. See Fig. 3 below
Dimensions stated are for closure plate supplied
Check the operation of the chimney as follows:-
Fig. 3
660mm
390mm to
CTR
Apply a smoke match to the flue spigot opening in the closure plate and observe
the smoke. If there is a definite flow into the opening then proceed with the instal-
lation. If there is not a definite flow into the opening, pre-heat the chimney for
about two minutes and retest for flow. If there still is no definite flow into the open-
ing, the chimney may require attention. DO NOT FIT THE FIRE-SEEK EXPERT
ADVICE.
Supplied By www.heating spares.co Tel. 0161 620 6677
460mm
Spigot Opening
168 x 68mm
305mm Minimum
440mm Maximum
Air Relief Openings
10
Closure
Plate
Dimensions
Fireplace
Opening
Dimensions
525mm Minimum
650mm Maximum
Minimum 10mm
Flat Sealing Area

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frlcn0mn

Table of Contents