Conditions Of Installation; Flue & Chimney Suitability - Flavel FRLCP0MN Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

1.1

CONDITIONS OF INSTALLATION

In Great Britain :-
It is law that all gas appliances are installed only by a CORGI registered installer in
GB, in accordance with these installation instructions and the Gas Safety
(Installation and use) Regulations 1998. Failure to install appliances correctly
could lead to prosecution. It is in your own interest and that of safety to comply
with the law.
The installation must also be in accordance with all relevant parts of the Local and
National Building regulations where appropriate, the Building Regulations
(Scotland Consolidation) issued by the Scottish Development Department, and all
relevant recommendations of the following British Standard Code of Practice.
1.
B.S. 5871. Part 1. Installation of Gas Fires.
2.
B.S. 5440.: 2000 Parts 1 & 2. Installation of Flues & Ventilation.
3.
B.S. 6891. Installation of Gas Pipework.
4.
B.S. 6461. Part 1. Installation of Chimneys & Flues.
5.
B.S. 1251. Open Fireplace Components.
6.
B.S. 715.
Metal Flue pipes for Gas Appliances.
7.
B.S. 1289 Clay Flue blocks and Terminals.
8.
B.S. 7566 Installation of factory-made Chimneys.
Ventilation Requirements
For use in G.B. purpose built ventilation is not normally required for this
appliance.
In Republic of Ireland :-
For use in I.E. this appliance must be installed in accordance with the rules
in force by a competent person and used only in a sufficiently ventilated
space. Please consult document I.S. 813 : 1996 Domestic Gas Installation,
issued by the National Standards Authority of Ireland.
1.2
FLUE AND CHIMNEY SUITABILITY
The appliance is designed for use with conventional brick built chimneys or lined
chimneys and pre – fabricated flues. It is also suitable for use with pre-cast flue
blocks conforming to B.S. 1289 and metal flue boxes conforming to BS 715. All
flues must conform to the following minimum dimensions.
Minimum diameter of circular flues
Minimum effective height of all flue types
Minimum cross sectional area of Pre-cast Flues
Supplied By www.heating spares.co Tel. 0161 620 6677
125 mm
3 metres
122.7 cm 2
4