6-4.

Typical Stick Welding Connections And Control Settings

3/4 in.
wrench
crescent wrench
OM-286503 Page 32
Complete Parts List is available at www.MillerWelds.com
Stop engine.
This section provides general guide-
lines and may not suit all applications.
The control panel shows the typical set-
tings for welding with a 7018 (1/8 in.)
electrode. Consult the amperage se-
lection tables below if welding with oth-
er electrodes.
1 Work Clamp
2 Electrode Holder
3 Electrode
Selection
Table
Cover)
Connect Work cable to DC Negative (-)/AC
terminal and Electrode holder cable to DC
Positive (+) terminal on welding generator.
Be sure to use the correct size weld ca-
bles (see Section 5-8).
For best performance, set the Coarse
Range switch to the lowest range that
covers the desired weld amperage.
Use the Fine control to select the de-
sired amperage within the range se-
lected. When properly set, the Fine
control is normally set at 7 or higher.
Typical
Settings
For
7018
Electrode:
� Set Coarse Range switch to 50-150 (1/
8") position.
� Set Fine control at 7 or higher for best
results.
Miller recommends Hobart filler metals.