Beware of the high dead weight of the device when transporting. Ensure that
your fingers do not get crushed when setting down the device.
Always install the device on a flat, stable non-slip base.
Pay attention to the vessels on the shaking table when setting the shaking rate.
This will prevent any of the medium to be shaken from spurting out of the
sample vessels.
All accessories and vessels in place for the shaking process must be firmly
secured.
Shaking vessels which are not properly secured could get damaged or be
projected out, thus causing injury. It is essential to regularly check that the
vessels to be shaken and the attachments are firmly secured, especially before
using the device again.
If you notice that the device is not running smoothly, the speed must always be
reduced until no more unevenness occurs in the operation.
Because of improper loading and the position of the center of gravity, dynamic
forces may arise during the shaking process that cause the shaker to move on
the table. For limits on the load or the weight placed on the shaking table at
high shaking frequencies, please refer to the diagram in the section "Supported
weight (load)".
After an interruption in the power supply during a shaking procedure, the
device does not restart by itself in operating mode A (factory setting).
Additional hazards to the user may occur if inflammable materials are used dur-
ing the shaking operation.
Furthermore, the shaking device may only be used to mix those materials or
material mixtures that the user knows will not react dangerously to the extra
energy produced by the shaking. This also applies to extra energy by means of
solar radiation during the shaking procedure.
Do not use the device in explosive atmospheres, it is not EX-protected.
With substances capable of forming an explosive mixture, appropriate safety
measures must be applied, e.g. working under a fume hood.
To avoid body injury and property damage, observe the relevant safety and
accident prevention measures when processing hazardous materials.
Accessories may only be assembled once the plug has been disconnected.
The safety of the user cannot be guaranteed if the device is operated with
accessories that are not supplied or recommended by the manufacturer or if
the device is operated improperly, contrary to the manufacturer's specifications.
The original IKA cable layout must be restored following servicing!
Even small undetectable damage may result in serious damage to the motor bear-
ing. Careful handling will guarantee safe work and a long service life of the device.
The device can only be disconnected from the power supply by pulling out the
power plug or the connector plug.
The socket for the power cord must be easily accessible.
The power switch of the device must be accessed immediately, directly and
without risk at any time. If access to the power switch cannot be ensured, an
additional emergency stop switch that can be easily accessed must be installed
in the work area.
If the device is controlled remotely (e.g. via a PC with labworldsoft
ensured that the device, including attachment and vessels, is in a safe condition
for the shaking process and that no other persons are endangered. Pay attention
to the marked areas in Figure 1.

Intended use

The KS 130 control / KS 130 control NOL and KS 260 control / KS 260
control NOL, HS 260 control / HS 260 control NOL are suitable for using
with various attachments for mixing liquids in bottles, flasks, test tubes and bowls
for a maximum supported weight of 2.0 kg and 7.5 kg.
The devices are designed for use in laboratories. The motion of the shaking table
or of the containers placed on it is circular or horizontal.
The devices are designed for use in laboratories. The movement of the shaking
table or the placed vessels is circular (KS) or horizontal back and forth (HS).
For proper use, place the device on a stable, even and no-slip surface. Ensure there is
sufficient space from the device to other objects and that the device does not move
during the shaking process.