Technical Specifications - Videx ESVK/6488 Series Manual

“2 wire” bus one way, two way videokit
Table of Contents

Advertisement

ESVK/6488 Series "2 wire Bus" videokit
Art. 4384
Speaker unit with built-in camera
Art. 4384X
Speaker unit with built-in camera & proximity key reader
CAMERA NOTES
FIELDS OF VIEW
The fields of view for standard camera are 55° for vertical angle and 115° for horizontal angle
while for Wide Angle camera are 80° for vertical angle and 170° for horizontal angle.
195 cm
Vertical angle
170 cm
80°
100 cm
75 cm
70 cm
Standard camera
CONNECTION TERMINALS SIGNALS
ART. 4384 VERSIONS
VID2
Video signal input (coax centre core)
GNDV Video signal ground (coax screen and 0V to camera)
Output to supply the external camera
+V2
if necessary
BUS
BUS Connection terminals
BUS
PTE
"Push to exit" active low input
GND
Ground
NO
Door open relay normally open contact
C
Door open relay common contact
+C
Electric lock capacitor discharge output
35Vdc power supply input (if used, the module is
VAUX
powered locally and not from the BUS)
Door open relay normally closed
NC
contact

TECHNICAL SPECIFICATIONS

Call buttons:
Working voltage:
Power consumption:
Working Temperature:
ESVK/6488 Series - Installation handbook
Horizontal angle
55°
135 cm
Wide Angle camera
Max 12Vdc
Max 12-24
Max 12-24
Up to 94
Supplied by the BUS line
Stand-by: 50 mA
Operating: 165 mA
-20 +60 °C
180 cm
105 cm
170°
115°
ART. 4384X VERSIONS
VID2
GNDV Video signal ground (coax screen and 0V to camera)
+V2
150mA
BUS
BUS
PTE
GND
NO
Vac/dc 2A
C
+C
VAUX
NC
Vac/dc 2A
GND
B
A
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.
- 16 -
MAXIMUM ILLUMINATION DISTANCE
FROM CAMERA AT NIGHT
The illumination LED's within the camera
will illuminate the visitor when they are
within 50 cm of the camera.
MAX 50 cm
70 cm
Video signal input (coax centre core)
Output to supply the external camera
if necessary
BUS Connection terminals
"Push to exit" active low input
Ground
Door open relay normally open contact
Door open relay common contact
Electric lock capacitor discharge output
35Vdc power supply input (if used, the module is
powered locally and not from the BUS)
Door open relay normally closed
contact
Ground
RS-485 serial interface
Max 12Vdc
150mA
Max 12-24
Vac/dc 2A
Max 12-24
Vac/dc 2A
66550031-EN - V6.1 - 15/08/20