POSITIONING:
Position the appliance in the center of the room to be conditioned if at all
possible. However, if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the appliance must have clear space
around them and not be obstructed in anyway. The unit must also be on a
level surface.
Appliance shall be installed, operated and stored in a room with a floor area
2
larger than 4M
.
WIRING:
The unit is fitted with a 12A circuit breaker and a 16A plug. Connect to a
suitably protected power supply
110V supply
Brown
Blue
Green/Yellow
DRAINAGE:
The appliance is fitted with a condensate pump which collects all the
condensate. As the condensate pump fills with water it will automatically
activate and empty via the tube outlet located at the back of the dehumidifier,
this should be connected to a water container or permanent drain. If the pump
fails, then the dehumidifier will automatically switch off. NOTE: after the pump
has emptied there will still be a small amount of water standing in the pump
reservoir which will leak if the dehumidifier is not kept upright.

INSTALLATION

Live
Neutral
Earth (ground)