POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway. For correct
installation and operation the unit must have a clearance of 0.5M from all
adjacent surfaces and or structures
WIRING:
Connect the power mains cable to a designated circuit breaker as follows:-
For Models without plugs:-
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified person in order to avoid hazard.
DRAINAGE:
The CS90H has an integral water pump fitted as standard. This condensate
pump is capable of discharging the condensate water 4.3m vertical lift away
from the unit & 30m horizontal. The water can, therefore, be discharged into a
drain some distance away. Please attach a suitable hose to the outlet of the
unit.
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk

INSTALLATION

Brown
Blue
Green/Yellow
Page 4 of 12
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Drawing : - TPC444
Issue
: - 3
Date
: - 24/11/16
Live
Neutral
Earth (ground)