POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway.
WIRING:
Connect the power mains cable to a 5 or 13 Amp power supply. As follows:-
DRAINAGE:
Connect a 12.5mm inside diameter hose to the condensate outlet pipe
(positioned centrally, beneath the air inlet grille). Secure the hose using a
worm drive clip. The hose should at no point be raised higher than the outlet
pipe. Hose should be ran to a permanent drain. Failure to observe this
requirement will result in flooding of the dehumidifier.

INSTALLATION

230V supply
Brown
Blue
Green/Yellow
Page 4 of 16
Drawing : - TPC137
Issue
: - 7
Date
: - 23/11/16
Live
Neutral
Earth (ground)