The Adjustable Humidistat: The CD-35 dehumidifier unit is fitted with a
control humidistat which measures the relative humidity of the air within the
room.
The humidistat incorporates a pointer and scale, which can be
adjusted, and set to a relative humidity level that is acceptable to maintain the
required conditions within the room. The humidistat controls the on/off
function of the dehumidifier. When the relative humidity of the air in the room
falls below the set point of the humidistat the dehumidifier will switch off, but
when the relative humidity of the air starts to rise again and passes the set
point the unit will switch on. The humidistat is used for the on/off function as it
is a cost effective method which ensures power is only used when needed.
Condensate pump: The CD-35 dehumidifier unit can be fitted, either in the
factory, or as retro-fit, with a condensate pump. This condensate pump will
allow the unit to run unattended, with the condensate run off to a permanent
drain and can be used up to 13 feet (4 meters), below the level of a
permanent condensate drainage point.
After removing the CD35 from its shipping container, visually check for signs
of damage. If there is evidence of damage, do not operate. Call your supplier
for advice. Do not discard the packing as it will be useful when transporting
the machine in the future.
Wiring: Connect the power cord to a grounded single phase, 15 Amp fused,
standard household wall socket.
Single Room: Position the CD35 in the center of the room to be dried.
However, if a damp patch is particularly apparent, the outlet grille should be
directed towards it. If the CD35 cannot be positioned centrally, a minimum
space of 6" should be allowed around the dryer.
Several Rooms: To dry a number of rooms simultaneously with the most
efficiency, the dryer as to be positioned between the rooms. Ensure that all
doors are left ajar allowing a patch for the air to circulate to the unit. An
auxiliary circulation fan would be helpful.