INDUSTRIAL DEHUMIDIFIER
OWNER'S MANUAL
www.eipl.co.uk
RM85H
Page 1 of 12
Drawing : - TPC433
Issue
: - 2
Date
: - 24/11/16

Advertisement

Table of Contents
loading

Summary of Contents for EIP RM85H

  • Page 1 Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 RM85H INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.uk Page 1 of 12...
  • Page 2: Package Contents

    Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 RM85H PACKAGE CONTENTS Item Description Quantity 10560RH-US Dehumidifier 3086144 Quick release hose coupling 3944110 PVC Tube – 3/8” I/D 7.8M TPC433 Manual Page 2 of 12...
  • Page 3 Designed for a wide range of applications, the RM85 is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying. The RM85H has a number of special features: • High efficiency rotary compressor •...
  • Page 4: Specifications

    Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 SPECIFICATIONS : 10560Rh-US ODEL : 37.2” (945mm) EIGHT : 21.5” (545mm) IDTH : 19.4” (492mm) EPTH : 99 lbs (45 Kg) EIGHT : 230 CFM (390 M3/hr) IRFLOW : 110V/ 60Hz/ 1 ph OWER UPPLY...
  • Page 5: Operation

    : - 2 Date : - 24/11/16 OPERATION The following procedures should be followed to test the RM85H for correct operation: After unpacking, examine all external features to confirm damage- free shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet.
  • Page 6 ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT LEAST FIVE MINUTES BEFORE RESTARTING. After using the RM85H, turn it off for five minutes to allow the condensate on the coils to drain into the pump reservoir, then press the momentary pump purge switch for twenty to thirty seconds to evacuate the water from the pump reservoir.
  • Page 7: Routine Service

    Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
  • Page 8 Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault.
  • Page 9: Troubleshooting

    Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 TROUBLESHOOTING YMPTOM AUSE EMEDY 1. No power to unit 1. Check the power from power supply panel Unit inoperative 2. Humidity Control set too 2. Check setting of control high 1.
  • Page 10 Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 RM85 SPARE PARTS LIST ESCRIPTION UMBER UANTITY UMBER Timer 1619508 Condenser coil 2029322 Evaporator coil 2029323 Cable & Tube wrap 2056002 Drain tray 2056003 Filter 2056004 Capillary 3014254 2 X 2ft Solenoid valve 3020837...
  • Page 11 Drawing : - TPC433 Issue : - 2 Date : - 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
  • Page 12 DL14 9AD Tel: +01 757 873 6800 Tel: +49 3043 557241 Tel: +44 (0) 1388 664400 Fax: +01 757 873 3632 Fax: +49 3043 557240 Fax: +44 (0) 1388 662590 www.ebacusa.com www.eip-ltd.de www.eipl.co.uk sales@ebacusa.com sales@eip-ltd.de sales@eipl.co.uk Page 12 of 12...