schmersal PSC1 Series Installation Manual page 49

Hide thumbs Also See for PSC1 Series:
Table of Contents

Advertisement

Installation manual
Safety instructions:
PL d or higher according to EN ISO 13849-1 is achieved on the usage of switching elements /
sensors with positively opening contacts or positive actuation according to EN 60947-5-1.
When using sensors with no positive break contacts, the "Universal Input Module" macro
(group) must be used in SafePLC2. (Please refer to SafePLC2 manual 12.3.2)
The usage of devices with switching elements for which a fault exclusion for a double fault can
be assumed for the safety level required is allowed. Reference is made to the applicable
stipulation in the EC Machinery directive 2006/42/EC.
PSC1-C-10 Installation manual V2.7
Version: 57E
Page 49 of 174

Advertisement

Table of Contents
loading

Table of Contents