schmersal PSC1 Series Installation Manual page 173

Hide thumbs Also See for PSC1 Series:
Table of Contents

Advertisement

Installation manual
Sensor
Switch type
Remark
1 normally closed
Simple sensor input
contact
1 normally open contact Simple sensor input
2 normally closed
Sensor input for increased
contact
requirement
2 normally closed
Monitored sensor input
contacts time
monitoring
1 normally open contact
Sensor input for increased
+ 1 normally closed
requirement
contact
1 normally open contact
Monitored sensor input
+ 1 normally closed
contact time monitored
Start / Reset
Switch type
Remark
1 normally open contact Simple alarm reset (edge
evaluation)
1 normally open contact Simple logic reset
1 normally open contact Simple start monitoring
(special function)
Note:
The alarm reset input can be operated with a continuous voltage of 24 V and is edge controlled.
PSC1-C-10 Installation manual V2.7
Version: 57E
Category categorisation SIL categorisation
PL d
PL d
PL e
PL e
PL e
PL e
Category categorisation SIL categorisation
--
PL d
--
SIL 2
SIL 2
SIL 3
SIL 3
SIL 3
SIL 3
--
SIL 2
--
Page 173 of 174