Appendix; Appendix A - Categorisation Of The Switch Types - schmersal PSC1 Series Installation Manual

Hide thumbs Also See for PSC1 Series:
Table of Contents

Advertisement

Installation manual

13 Appendix

13.1 Appendix A – categorisation of the switch types
General note:
The individual switches for the following input elements can be assigned as required to the digital
inputs I0 to I13.
Enable switch
Switch type
Remark
1 normally closed
Simple enable switch
contact
1 normally open
Simple enable switch
contact
2 normally closed
Enable switch for increased
contacts
requirement
2 normally closed
Monitored enable switch
contacts time
monitoring
Emergency stop
Switch type
1 normally closed contact EMERGENCY STOP simple PL d
2 normally closed contact EMERGENCY STOP for
2 normally closed
contacts time monitoring
(1)
Fault exclusions and boundary conditions according to EN ISO 13849-2 are to be observed!
Door monitoring
Switch type
Remark
2 normally closed
Door monitoring for
contact
increased requirement
2 normally closed
Monitored door monitoring PL e
contacts time
monitoring
1 normally open
Door monitoring for
contact + 1 normally
increased requirement
closed contact
1 normally open
Monitored door monitoring PL e
contact + 1 normally
closed contact time
monitored
2 normally open
Door monitoring for
contact + 2 normally
increased requirement
closed contact
PSC1-C-10 Installation manual V2.7
Version: 57E
Remark
increased requirement
EMERGENCY STOP
monitored
PL categorisation
according to EN ISO
13849-1
PL d
PL d
PL e
PL e
Category categorisation SIL categorisation
1)
PL e
PL e
Category categorisation SIL categorisation
PL e
PL e
PL e
SIL categorisation
according to EN 61508
SIL 2
SIL 2
SIL 3
SIL 3
SIL 2
SIL 3
SIL 3
SIL 3
SIL 3
SIL 3
SIL 3
SIL 3
Page 171 of 174