Installation manual
V_Ist
SOS_Result
Reset_In
Process value (speed) => no change to the output status on reset in the alarm state
Max. 3 sec
I1
Q =I1 AND I2
I2
IN_Result
Reset_In
Alarm_Status
Time-based function => reset the output status, triggering if limit exceeded again
Safety instructions:
•
For time-based functions, e.g. monitoring of the timing of complementary input signals, the
output status is reset and a state defined as erroneous only detected if the (time) limit is
exceeded again.
•
To protect against incorrect usage, e.g. repeated triggering of the reset function to bypass an
alarm state, if necessary applicative measures must be taken in the PLC programming.
PSC1-C-10 Installation manual V2.7
Version: 57E
V_Is t > SOS_V_Max
Max. 3 sec
Max. 3 sec
Q =I1 AND I2
Q =I1 AND I2
Page 130 of 174