Beckhoff KS31 2 Series Manual page 53

Two channel accurate analog terminals
Table of Contents

Advertisement

Bit
Name
R37.1
SkipFIR
R37.0
Fast
Examples
Value in R37
0x35C0
0x2660
0x1330
0x7FF1
0x3FF1
0x1001
Value in R37
0x7FF2
0x3FF2
0x1002
R40: Calibration interval
This register contains the calibration interval for the terminal's automatic calibration. The unit is 100 ms. The
automatic calibration can be activated through bit R32.5 [} 50] in the feature register.
R44: Forced calibration interval
This register contains the interval for the terminal's forced calibration. This interval is always a multiple (the
default is 3
) of the calibration interval. (R40 [} 53]). The interval for forced calibration when the terminal
dec
leaves the factory is therefore 3 x 180 s = 540 s. The forced calibration can be activated through bit R32.5
[} 50] in the feature register.
R47: Number of stable measured values
This register contains the number of stable measured values recorded during the calibration.
R48: Tolerance for measured value stability
This register contains the specified stable measured value tolerance.
KL31x2/KS31x2
Description
0
FIR filter is active.
bin
1
FIR filter is bypassed.
bin
0
Fast Step Mode is not active.
bin
1
Fast Step Mode is active: a fast reaction will follow jumps at
bin
the input, in spite of the filter stage being active. In this case
the filter is bypassed!
F
Stop
50 Hz
70 Hz
140 Hz
F
Limit
39.6 Hz
77.36 Hz
158 Hz
Version: 2.6.0
Data structures
Cycle time
140 ms
100 ms
50 ms
40 ms
20 ms
<4 ms
Cycle time
40 ms
20 ms
<4 ms
Default
0
bin
0
bin
53