Overview
Cut Once
Cuts the media in the current position.
Delete Page
Deletes the page currently in memory and ready to print.
Lock Operator Panel / Unlock Operator Panel
Once executed, the front panel will be locked or unlocked. When locked,
the panel can still be accessed through the virtual front panel of the
Printronix Remote Management Software Advanced Tool Kit. If the
Disable Event Parser has been executed, the front panel will be unlocked.
None
An action that stops actions. If connected to a key pressed event, that key
is effectively disabled.
Enable GPIO Events / Disable GPIO Events
These actions allow you to switch on or off the event parsing of GPIO.
When disabled, the only action GPIO will execute is the enable event
parser action.
Reply to Host
The Reply to Host action allows the user to specify a data stream that will
transmit to the host when the selected event takes place and to select the
interface that should be used for this data transmission. Data entry can be
in ASCII or in hexadecimal. The entry mode can be selected with the
arrow keys: up-arrow for ASCII entry mode and down-arrow for Hex entry
mode.
Figure 16. Setting Reply to Host Action Parameters
Wait
The parameter for this action specifies the time (in 1/1000 seconds) that
GPIO will wait until the next action executes.
PAA Control: CST Reset
This action resets the Use Once flags of the currently active PAA CST.