Bellfires VIEW BELL YORK 3 CF Installation Instructions & Manual For Maintenance page 56

Gas fires with closed combustion system
Table of Contents

Advertisement

Bellfi res
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check if the overpressure hatches are correctly positioned and check if the
packing seals properly under the hatches.
• Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake. Also check that all connections are secure.
56
English
Installation instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

View bell york 3 lf

Table of Contents