Mantle iron (option).
The optional mantle iron is intended for supporting the brickwork above the appliance.
The mantle iron must rest on the brickwork on both sides so that upward building is
possible. Level the mantle iron with the supplied bar set.
First remove the 2 mantle iron transport-spacers "REMOVE"
Temporarily support the mantle iron, so that it does not fall forwards.
Note!
Installation instructions
Mantle iron in combination with the 10 cm
frame (option). The mantle iron is screwed
on the top panel of the 4 sided 10 cm
frame at the factory.
Do not unscrew this connection !
Bar set: • 2x draw bars
• 2x tension sleeves
• 2x M6 hooks
• 2x brass expansion
plugs M6