1.7.1 Gas connection operating unit
Important:
During gas connection, take care not to twist the gas
regulator block. Make sure that both the gas regulator
block and the supply pipes are not subjected to stresses.
The appliance is supplied with a built-in operating unit.
Frame with
door (white)
Figure 18: Operating unit
Remove the decorative edging and door of the operating unit.
Fit the separate operating unit, where the gas regulator block and receiver will be
placed, on max. 50 cm from the appliance.
The burner, gas regulator block and receiver have been fully factory assembled.
Disconnect the bracket with the gas regulator block and receiver from the appliance.
Carefully move the bracket with the gas regulator block, receiver, pipes and cables to
the operating unit. Mount the bracket at the bottom of the operating unit.
Important:
Take care that no pipes get damaged and no compression fi ttings
come loose when moving the gas regulator block. Prevent twisting
the fl exible pipes! Check all compression fi ttings for leaks
afterwards!
Mount the receiver in the top of the operating unit. Check afterwards that all electric
connections are properly connected.
General:
Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity.
During subsequent installation of the operating unit, protect the gas regulator block and
piping against encasement by cement etc.
Installation instructions
Operating unit
English
33