1.7.7 Baffl e plate
The appliance is factory supplied with a baffl e plate. This baffl e plate is located at the
top of the combustion chamber, just before the connection with the concentric fl ue.
The baffl e plate only remains on location, if a
See section 1.7.6.
Important:
Figure 29: Removing the baffl e plate
Remove the baffl e plate, by unscrewing two bolts.
Screw the bolts back into the ceiling of the combustion chamber, after the baffl e plate
has been removed.
Installation instructions
Removing the baffl e plate!
Always remove the baffl e plate if there is no need to
mount a restriction plate!!!
No restriction plate → No baffl e plate !!!!!
Failure to remove the baffl e plate, if there is no
need to mount a restriction plate, can lead to
dangerous situations!
restriction plate
needs to be mounted.