Digital I/O
To use digital input or output to control other devices, provide
feedback to the receiver, or trigger actions, connect devices to
the digital I/O ports (see
in the following diagram.
DIGITAL I/O
HCR 102
Rear
Con gure each port as a digital input or output,
Panel
with or without +5 VDC pull-up. Use these ports to:
1
2
G
3
4
G
• Monitor or trigger events and functions (toggle relays,
• Trigger LEDs, incandescent lights, or other devices
Ground
Switch,
G
4
Sensor
3
G
Indicator
2
LED
1
HDMI/CEC
Connect an AV device that supports CEC control to the
HDMI/CEC output port on the receiver (
to automatically turn display power on or off based on whether
an active signal is detected at the selected input.
The HCR 102 sends CEC driver commands to the display for
basic control functions. CEC control is pre-configured and works "out of the box" but it can be customized further using GC.
NOTE:
It can take up to 2 minutes after powering up the receiver to initiate CEC display control.
Grounding
If the HCT 101 EU or HCT 101 MK transmitter is not mounted to a grounded metal
junction box, Extron recommends connecting the unit to an earth ground to protect
the unit from electrostatic discharge.
To ground the unit:
Securely terminate a grounding cable with a ring terminal.
1.
Remove the grounding screw in the upper right corner of the rear panel, insert
2.
the grounding cable, replace and securely fasten the screw (see the figure at
right). Do not overtighten the screw. Maximum torque is 2 inch-pounds (0.2
Newton-meter).
Connect the other end of the grounding cable to an earth ground.
3.
12
figure
3,
M
on page 3) as shown
Digital I/O (digital input/output)
issue commands, send e-mail), once con gured.
that accept a TTL signal.
Share the
same ground
among I/O
Wire
connections.
Nut
Device 4
Device 3
Device 2
Device 1
G
) to allow the HCR 102
LAN
Connect the receiver to a network via the LAN port (
for remote monitoring and configuration of the system,
for touchpanel control, or to allow the receiver to control an
Ethernet-enabled product. You will need the MAC address
(
O
) during device discovery and configuration.
Insert Twisted
RJ-45
Connector
Activity
LED
2
2 2
(Switches,
sensors,
-XX-XX-XX
-XX-XX-XX
X
LEDs,
E######
E######
#
relays, or
similar
HCR 102 Rear Panel
items)
NOTE: The factory configured password for this device has
been set to the device serial number. Passwords are case
sensitive. Performing a Reset to Factory Defaults reset (see
Reset Modes: a Brief Summary on page 17) sets the
password to extron.
OUTPUTS
LINK
L I
L
I N
N K
N
K
K
HDMI/CEC
HCR 102 Rear Panel
Ethernet
TCP/IP
Network
Pair Wires
NOTE: Initial units ship with
the functions of these LEDs
reversed. Subsequent
units will ship with
standard LED functions.
LAN (Ethernet)
Default protocol:
• IP address: 192.168.254.250
Pins:
• Gateway IP address: 0.0.0.0
8
7
6
5
4
3
2
1
• Subnet mask: 255.255.255.0
Link
• DNS address: 127.0.0.1
LED
• DHCP: off
• Link speed and duplex level:
LAN
autodetected
• Data rates: 10/100Base-T
Default login credentials:
• Username: admin
LAN
• Password: extron
MODEL 80
AUDIO
A
A
A
A
A
U
U
U D
D
D
D
D
D IO
O
O
O
L
L
L
L
L
L
R
R
HDMI
CEC
CEC-Compliant Display
HCT 101 EU Rear Panel
POWER
12V
0.7
A MAX
HCT 101
Figure 9.
Connecting a Grounding
Wire to the HCT 101 EU
or HCT 101 MK
N
)
PC
AV Device
FLAT PANEL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HC 402 EU and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Hc 402 mk

Table of Contents