6.1.4 Elevator Board / Floor Hardware Test - 1835 and 1837 Systems Only
This testing sequence will allow you to check activation of individual relays on the elevator control board(s) and will confirm
communication between the telephone entry system circuit board and the elevator control board(s).
PQRS
PQRS
PQRS
PQRS
1. Press
and enter your four-digit MASTER CODE
7 7
7 7
The LCD display will show: WHICH ELEVATOR?
2. Enter the elevator shaft number (1, 2, 3 or 4) _, then press
The LCD display will show: FLOOR?
3. Enter the two-digit floor number _ _ , then press
Note: First floor is entered 01, fifth floor is entered 05 etc.
4. The relay LED on the elevator control board that represents the floor number entered will turn ON for approximately
1 second.
5. To check other floor relays, repeat steps 2 and 3.
OPER
OPER
6. Press
TOGETHER to end this programming sequence (beeeeeep).
0 0
Note: This program test sequence will automatically end itself if no keypad inputs are detected after approximately
30 seconds.
Refer to the Elevator Control board installation manual for more information on troubleshooting the elevator control boards.
6.1.5 Automatic Hang-up Options - 1835 and 1837 Systems Only
This sequence will allow you to program different methods by which the telephone entry system will hang-up if a resident
denies a guest access by hanging up their telephone rather than pressing the "#" key to terminate the call.
Factory setting is 1, dial tone detect ON.
GHI
GHI
OPER
OPER
1. Press
and enter your four-digit MASTER CODE
4 4
0 0
The LCD display will show: 0=N 1=DT 2=SIL 3=BTH.
0 – BOTH OFF. Unit hangs up after programmed strike time runs out.
1 – DIAL TONE detect ON. Unit hangs up after detecting 5-seconds of dial tone.
2 –SILENCE detect ON. Unit hands up after detecting 15-seconds of silence.
3 – BOTH ON.
2. Enter the hang-up option code _ (0, 1, 2 or 3), then press
OPER
OPER
3. Press
TOGETHER to end this programming sequence (beeeeeep).
0 0
6.1.6 Modem Output Level Adjustment
This programming step should only be used if you are experiencing modem trouble. It allows you to adjust the output level of
the modem tones. A higher modem level number increases the tone volume while a lower number decreases tone volume.
1-Min, 8-Max.
Factory setting is 4.
WXYZ
WXYZ
OPER
OPER
1. Press
and enter your four-digit MASTER CODE
9 9
0 0
2. Enter the single-digit modem level number (1-8), then press
OPER
OPER
3. Press
TOGETHER to end this programming sequence (beeeeeep).
0 0